Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8538479
- Product Categories
- Friendly Links
- home > Supply > Supply of portable precision gas analyzer Model: ZX7M-ecom the KD library number: M370176
Information Name: | Supply of portable precision gas analyzer Model: ZX7M-ecom the KD library number: M370176 |
Published: | 2011-10-15 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Portable precision gas analyzer Model: ZX7M-ecom the KD library number: M370176 Portable Precision flue gas analyzer ZX7M-ecom KD for more information >>> midwest-group is suitable for continuous measurement and control a variety of industrial combustion equipment and industrial boiler combustion; Suitable for flue gas monitoring system CEMS comparison test, long-running work; Applicable to the emission monitoring and combustion debugging of portable continuous monitoring of thermal power plants, oil refineries, chemical plants, cement factories, research laboratories, heating / drying devices; ZX7M-ecom KD portable precision gas analyzer using electrochemical and infrared sensors can be configured for up to eight sensors. Industrial emissions monitoring and combustion boiler's long-term testing, tuning and maintenance, this is equipped with efficient Peltier gas cooler condensate detector and peristaltic pump. All components are long-term failure, 5-way signal input and 2 channel output to provide unprecedented flexibility. Feature Analytical measurement of O2, CO, CO2, NO and NO2, SO2 VGA video graphics background light touch LCD display Built-in dot matrix printer Online real-time traffic display Flue gas temperature and pressure measurement Calculate the value: CO2, combustion efficiency, excess air coefficient Automatic air cleaning function The program can be set sampling / decontamination cleaning automatic operation Temperature sensor can be added to the AUX input DAS 3.0 data acquisition software Built-in high-capacity data memory, RAM, up to 4MB RS232 interface Built-in Peltier cooler for continuous measurement Automatic discharge of the electronic monitoring of the condensate and the peristaltic pump Aluminum frame meter boxes, rugged Automatic monitoring for a long time measurement ZX7M-ecom KD portable precision gas analyzer equipped with improve the pretreatment unit, such as: fine filter, peristaltic pump, gas cooler, suitable for long time continuous analysis and monitoring. Measurement instrument capable of independent fresh air switch and sensor auto-calibration, automatic recording measurement data. Peltier gas cooler Dry the sample gas to the analyzer, the accuracy of the measurement values ??and equipment service life in terms of is absolutely necessary, especially in the case of the low flue gas temperature and high humidity flue gas, such as long measurement, analysis The instrument is equipped with high-power gas cooler, ecom-KD is to meet this requirement, its high-power Peltier gas cooler, suitable for long hours, can effectively protect the sensor, the measurement of accurate data. Heating diagnosis Heating diagnosis suitable for special measurement conditions and the point of the old device to directly measure the heat losses, after the end of the measurement for diagnosis (eg, within 24 hours) and to map out diagnostic data, and suggests that defects in the boiler combustion or combustion state and needs to be improved. User password key The instrument to normal operation in the case of electronic key can not operate the instrument without authorization, the key to pull out all the features of all of atresia, each instrument can authorize multiple users. Measurement parameters O2, CO, NO and NO2, SO2, temperature, pressure, black smoke Calculated values: CO2, NOx, combustion efficiency, heat loss, excess air ratio, flue gas dew point, mg/m3,, mg / kwh, the reference oxygen O2, and calculate the average (optional) Printer: high-speed printer, paper width 58mm Display: LCD display; 100 × 80 mm; a maximum of 17 lines, background light; graphic display; touch screen Handling and security of the sample gas ● fast gas transport (measuring gas, fast response time) ● pre-fine filters ● Automatic condensate emissions and monitoring ● Peltier gas cooler ● The instrument internal flow regulator ? CO over-range, turn-off protection, does not affect the measurement ● Automatic measurement mode (Automatic storage, automatic printing) ● cryptographic keys Data processing ● membrane keyboard data entry ● DAS program data collection ● Built-in printer RAM card to store measurement data Measurement data transmitted to the PC, and generate Excel format ● long measurement, automatic storage Specifications describe the ● The meter box: aluminum frame meter boxes ● Dimensions (W x H x D): approximately 510 × 300 × 260mm ● Weight: about 14kg ● The battery-powered: 12V/3.4Ah ● AC power supply: 230V50Hz/110V60Hz ● Operating temperature: +5 to +40 ° C ● Storage temperature: -20 ~ +50 ° C Technical parameters to measure the units of the parameter measuring range precision-resolution sensor type O2 0-21% vol vol% + / - 0.2 vol 0.1% of the electrochemical sensors Of CO 0-10000ppm ppm, + / - 5ppm or measured value of 5% 1ppm electrochemical sensors Of CO 4000-63000ppm ppm, + / - 5ppm or measured value of 5% 1ppm electrochemical sensors Of NO 0-5000ppm ppm, + / - 5ppm or measured value of 5% 1ppm electrochemical sensors Of NO2 0-1000ppm ppm + / - 5ppm or measured value of 5% 1ppm electrochemical sensors Of SO2 0-5000ppm ppm, + / - 5ppm or measured value of 5% 1ppm electrochemical sensors Of H2S 0-1000ppm ppm, + / - 5ppm or measured value of 5% 1ppm electrochemical sensors The CxHy 0-2000ppm ppm + / - 3% of 1ppm 4ppm or measuring the value of the IR infrared sensors CO2 0-20% vol.% + / -0.3% Or 3% to 0.1% of the measured values ??IR infrared sensors Flue gas temperature 0-650 ℃ / 1200 ℃ ℃ + / - 1 ° C or 1% of measured value 0.1 ℃ NiCrNi An ambient temperature of 0-99 ° C ° C + / - 1 ℃ and 0.1 ℃ semiconductor Flue gas pressure + / - 100hPa hPa + / - 2% 0.01hPa pressure sensor Black smoke measuring 0-9 1 - the scale table Calculate the value parameter symbol Range resolution principle Heat losses qA 0 ... 99.9% to 0.10% Combustion efficiency ETA 0 ... 99.9% to 0.10% Excess air ratio Lambda 1 ... 0.01 computing CO2 CO2 0 ... CO2 max 0.1vol.% Calculation Chinese and Western Group Portable precision gas analyzer ZX7M-ecom KD |
Admin>>>
You are the 30146 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Pharmaceutical Co., Ltd. North Investor All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 30146 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Pharmaceutical Co., Ltd. North Investor All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility